EB-AC2201 Controller

PRODUCT DESCRIPTION

The EB-AC2201 controller is the basic module responsible for access control of the Integrated Management System (IMS).

Its task is to supervise the work of AC-PA01 proximity card readers as well as control and check the status of the door. The controller can be connected to two readers in the case of two-way door control.

To increase security and to expand access control functionality, the entire decision-making process has been moved to the central unit of the system. Thanks to this solution, restrictions resulting from the reader’s memory capacity were removed. It is also not possible to cause an unauthorized opening of the door and every event, including the attempted burglary or tampering with the controller, is recorded in the event history.

The EB-AC2201 controller has the ability to directly control the electromagnetic lock or via the EB-LCM11 or EB-LCM21 bolt controllers.

Quick exchange of information with the management devices allows immediate reaction to the fact of reading the card or changing the input states of the controller.

In addition, the controller has:

  • the option of connecting a door opening button when no supervision is needed
  • outgoing people,
  • universal input,
  • LOCK socket giving the possibility of connecting passages in the so-called airlock *,
  • additional output enabling e.g. control of a second lock,
  • tamper socket to which a housing opening sensor can be connected,
  • emergency power supply system that requires an external battery.

Technical parameters:

Power supply:POWER input

DC voltage with nominal value of 12V,

Permissible controller supply voltage 10-17V.

Power consumption:The controller working independently consumes from 60 to 150mA,
Outputs:The controller is equipped with two outputs, the first of which is by default set as the control output of the lock. High condition occurs when the COM and NO contacts short circuit.

The load on each output is:

– 50V AC, 1A

– 24V DC, 2A

When using locks that require a higher supply voltage or higher power, an additional external relay must be used.

Inputs:The controller is equipped with three potential-free inputs.

– UNI.IN universal input, the operation of which depends on the software configuration.

-DOOR CONTACT input for connecting the door sensor – reed switch. It is also possible to use it as a universal input.

– OPEN BUTTON input intended for connecting the door release button from the inside, or universal input.

However, the button operation always depends on the system configuration and the input alone cannot force the controller to react. High condition occurs when pins short-circuit. 50 ms input filter.

Reader input:ANTENNA input

Used to connect the reader or access control readers. Two AC-PA01x readers can be connected to this input, provided that one is master and the other slave.

Wymiary:Panel dimensions without cover:

height 122mm, width 120mm, height of the highest element 50mm